Within this area, there are two furnace types; MTF and CTF models have an integral work tube, while the G range of furnaces is modular and requires a separate work tube.



Horizontal Tube Furnace MTF modelstube

  • Maximum operating temperatures Horizontal Tube Furnace is 900C, 1000C and 1200C
  • Tube diameters range from 15 - 38mm
  • Heated lengths from 130 - 400mm
  • These models utilise a resistance wire heating element wound around a ceramic worktube, forming an integral part of the heating element to ensure excellent thermal uniformity
  • Rapid heat up to operating temperature
  • Can be adapted to allow a non-oxidising atmosphere or vacuum, by fitting an additional worktube and end seals
  • The thermocouple is located in a protected position between the outside of the worktube and heating element, allowing the full worktube diameter to be used
  • Normally built on the horizontal base pictured left, this furnace range can optionally be mounted vertically with a separate control box
  • Applications in materials research include testing of novel materials under strict temperature and varying atmosphere conditions
  • Applications in the electronics industry include testing electronic components and semiconductor materials under inert atmospheres or vacuum.
  • Applications in instrumentation include testing of temperature sensors such as thermocouples and PT100's, which may require enhanced thermal uniformity

Horizontal Tube Furnace CTF modelstube

  • Maximum operating temperature Horizontal Tube Furnace is 1200C
  • Tube diameters of 65, 75 and 100mm
  • Heated lengths of 550, 700 & 900mm
  • These models utilise a resistance wire heating element wound around a ceramic worktube, forming an integral part of the heating element to ensure excellent thermal uniformity
  • Rapid heat up to operating temperature
  • Can be adapted to allow a non-oxidising atmosphere or vacuum, by fitting an additional worktube and end seals
  • The thermocouple is located in a protected position between the outside of the worktube and heating element, allowing the full worktube diameter to be used
  • Normally built on the horizontal base pictured left, this furnace range can optionally be mounted vertically with a separate control box
  • Applications in materials research include testing of novel materials under strict temperature and varying atmosphere conditions
  • Applications in the electronics industry include testing electronic components and semiconductor materials under inert atmospheres or vacuum
  • Applications in instrumentation include testing of temperature sensors such as thermocouples and PT100's, which may require enhanced thermal uniformity

 

Horizontal Tube Furnace GHA models - New models!tube

  • Maximum operating temperature Horizontal Tube Furnace is 1200C
  • Tube diameters from 19.5 - 150mm id
  • An integral worktube is not fitted and therefore a worktube must be ordered separately
  • Existing customer worktubes can be used - however, the outer diameter & length must be specified at the time of ordering
  • Seven heated lengths from 300 - 1200mm
  • Heating is provided by resistance wire heating elements, semi-embedded in rigidised vacuum formed low thermal mass insulation modules, which when used together with a ceramic worktube ensure excellent thermal uniformity
  • Rapid heat up to operating temperature
  • Optional removable tube adapters allow rapid changes for different size worktubes
  • Can be adapted to allow a non-oxidising atmosphere or vacuum, if required, by fitting an additional worktube and end seals
  • Applications in materials research include testing of novel materials under strict temperature & various atmosphere conditions
  • Applications in the electronics industry include testing electronic components and semiconductor materials under inert atmospheres or vacuum
  • Applications in instrumentation include testing of temperature sensors such as thermocouples and PT100's, which may require enhanced thermal uniformity


Vertical Tube Furnace GVA models - New models!

  • Maximum operating temperature Vertical Tube Furnace is 1200C
  • Tube diameters from 19.5 - 150mm id
  • An integral worktube is not fitted and therefore a worktube must be ordered separately
  • Existing customer worktubes can be used - however, the outer diameter & length must be specified at the time of ordering
  • Seven heated lengths from 300 - 1200mm
  • Heating is provided by resistance wire heating elements, semi-embedded in rigidised vacuum formed low thermal mass insulation modules, together with a separate ceramic worktube to ensure excellent thermal uniformity
  • Rapid heat up to operating temperature
  • Removable tube adapters allow rapid changes for different size worktubes
  • Can be adapted to allow a non-oxidising atmosphere or vacuum, if required, by fitting an additional worktube and end seals
  • This furnace range is supplied with a versatile stand kit, which allows the furnace to be mounted vertically on a stand or wall mounted, or bench mounted horizontally (shown left), all using the separate control box
  • Applications in materials research include testing of novel materials under strict temperature & various atmosphere conditions
  • Applications in the electronics industry include testing electronic components and semiconductor materials under inert atmospheres or vacuum
  • Applications in instrumentation include testing of temperature sensors such as thermocouples and PT100's, which may require enhanced thermal uniformity
  • For enhanced thermal uniformity, three zone models are available
tube
 