Jenway 6310 Scanning Spectrophotometer Visible 8nm
• Spectrum scanning across entire range from 320 to
1000nm (6310) or 198 to 1000nm (6315)
• Concentration measurements by
direct factor or by quantitation using up to 6 standards
• Kinetics
with real time graphical display of sample and standard
• Store up to
50 methods in each mode
• Pulsed xenon lamp (6315)
The
6310 and 6315 spectrophotometers introduce scanning, kinetics and
quantitation modes to the highly successful 63 series. The units will
meet the demands of a wide range of applications especially those in
clinical, veterinary, environmental, general QC and performance testing
areas. With a memory capacity of 50 methods for each mode, the fully
open operating system
ensures compatibility with reagent kits from
most manufacturers as well as enabling full customisation.
Technical Specification
|
Parameter
|
6310
|
|
Wavelength range
|
320 to 1000nm
|
|
Wavelength resolution
|
1nm
|
|
Wavelength accuracy
|
±2nm
|
|
Spectral bandwidth
|
8nm
|
|
Transmittance
|
0 to 199.9%T
|
|
Absorbance
|
–0.300 to 1.999A
|
|
Accuracy
|
±1%T
|
|
Resolution
|
0.1%T, 0.001A
|
|
Stray light
|
<0.5% at 340nm
|
|
Noise
|
<0.001A at 0A at 400nm
|
|
Stability
|
<0.002A/h after 30 minutes
|
|
Concentration range
|
–300 to 1999
|
|
Concentration resolution
|
Selectable 1, 0.1, 0.01 or 0.001
|
|
Calibration
|
Blank with a single standard or factor
|
|
Quantitation range
|
–300 to 1999
|
|
Quantitation resolution
|
Selectable 1, 0.1, 0.01 or 0.001
|
|
Calibration
|
Blank with up to 6 standards
|
|
Curve correction
|
Linear regression, interpolation or linear
regression through zero
|
|
Kinetics display
|
Graphical and calculated concentration value
|
|
Calibration
|
Against standard and factor
|
|
Correlation factor
|
r2 value displayed with result
|
|
Spectrum range
|
Any range between 320 and 1000nm
|
|
Scan interval
|
1, 2 or 5nm, selectable
|
|
Analysis
|
Absorbance and wavelength of peaks and valleys
|
|
GLP
|
Real time clock and calendar, Operator ID.
Supervisor security (locks all set up parameters). Method display lock
|
|
Light source
|
Tungsten halogen lamp
|
|
Outputs
|
Analogue and RS232
|
|
Power
|
<50W
|
|
Size (w x d x h)
|
365 x 272 x 160mm
|
|
Weight
|
6kg
|
| 630 501 |
£1,330.00 |
Spectrophotometers - 63 series |
Model 6300 Visible range Spectrophotometer
(320-1000nm) supplied with mains lead, pack 100 disposable cuvettes, 10 x
10mm cell holder, PC Application Software on CD-ROM* and operating
instructions, for use on 230V/50Hz. |
| 630 531 |
£1,330.00 |
Spectrophotometers - 63 series |
Model 6300 Visible range Spectrophotometer
(320-1000nm) supplied with US line cord, pack 100 disposable cuvettes, 10 x
10mm cell holder, PC Application Software on CD-ROM* and operating
instructions, for use on 110V/60Hz. |
| 631 001 |
£1,639.00 |
Spectrophotometers - 63 series |
Model 6310 Visible range Scanning Spectrophotometer
(320-1000nm) supplied with mains lead, pack 100 disposable cuvettes, 10 x
10mm cell holder, interface cable, PC Application Software on CD-ROM* and
operating instructions, for use on 230V/50Hz. |
| 631 031 |
£1,639.00 |
Spectrophotometers - 63 series |
Model 6310 Visible range Scanning Spectrophotometer
(320-1000nm) supplied with US line cord, pack 100 disposable cuvettes, 10 x
10mm cell holder, interface cable, PC Application Software on CD-ROM* and
operating instructions, for use on 110V/60Hz. |
| 631 501 |
£2,560.00 |
Spectrophotometers - 63 series |
Model 6315 UV/Visible range Scanning
Spectrophotometer (190-1000nm) supplied with mains lead, pack 100 disposable
cuvettes, 10 x 10mm cell holder, PC Application Software on CD-ROM* and
operating instructions, for use on 230V/50Hz. |
| 631 531 |
£2,560.00 |
Spectrophotometers - 63 series |
Model 6315 UV/Visible range Scanning
Spectrophotometer (190-1000nm) supplied with US line cord, pack 100
disposable cuvettes, 10 x 10mm cell holder, PC Application Software on
CD-ROM* and operating instructions, for use on 110V/60Hz. |
| 632 501 |
£1,330.00 |
Spectrophotometers - 63 series |
Model 6320D Visible range Spectrophotometer
(320-1000nm), fitted with domed lid, supplied with mains lead, dual cell
holder (for 10mm square cuvettes and 12.7mm diameter tubes) and operating
instructions, for use on 230V/50Hz. |
| 632 521 |
£1,330.00 |
Spectrophotometers - 63 series |
Model 6320D Visible range Spectrophotometer
(320-1000nm), fitted with domed lid, supplied with mains lead, dual cell
holder (for 10mm square cuvettes and 12.7mm dia tubes) and operating
instructions, for use on 110V/60Hz. |
| 635 001 |
£2,305.00 |
Spectrophotometers - 63 series |
Model 6305 UV/Visible range Spectrophotometer
(190-1000nm) supplied with mains lead, pack 100 disposable cuvettes, 10 x
10mm cell holder, PC Application Software on CD-ROM* and operating
instructions, for use on 230V/50Hz. |
| 635 031 |
£2,305.00 |
Spectrophotometers - 63 series |
Model 6305 UV/Visible range Spectrophotometer
(190-1000nm) supplied with US line cord, pack 100 disposable cuvettes, 10 x
10mm cell holder, PC Application Software on CD-ROM* and operating
instructions, for use on 110V/60Hz. |
| 636 001 |
£2,560.00 |
Spectrophotometers - 63 series |
Genova Life Science Analyser; dedicated
spectrophotometer for DNA/RNA oligonucleotide and protein analysis, supplied
with mains lead, 8 x 750µl UV plastic cuvettes, cell holder and operating
instructions, for use on 230V/50Hz. |
| 636 005 |
£4,999.00 |
Spectrophotometers - 63 series |
Genova Life Science Analyser; dedicated
spectrophotometer for DNA/RNA oligonucleotide and protein analysis, supplied
with TrayCell for ultra-micro sample volumes, mains lead and operating instructions, for use on 230V/50Hz. |
| 636 031 |
£2,560.00 |
Spectrophotometers - 63 series |
Genova Life Science Analyser; dedicated
spectrophotometer for DNA/RNA oligonucleotide and protein analysis, supplied
with mains lead, 8 x 750µl UV plastic cuvettes, cell holder and operating
instructions, for use on 110V/60Hz. |
| 636 035 |
£4,999.00 |
Spectrophotometers - 63 series |
Genova Life Science Analyser; dedicated
spectrophotometer for DNA/RNA oligonucleotide and protein analysis, supplied
with TrayCell for ultra-micro sample volumes, mains lead and operating instructions, for use on 110V/60Hz. |
| 637 001 |
£1,639.00 |
Spectrophotometers - 63 series |
Aquanova Environmental Spectrophotometer, Visible
range (320-1000nm), supplied with mains lead, 9 way serial cable, PC
Application Software on CD-ROM and operating instructions, for use on
230V/50Hz. |
| 637 031 |
£1,639.00 |
Spectrophotometers - 63 series |
Aquanova Environmental Spectrophotometer, Visible
range (320-1000nm), supplied with mains lead, 9 way serial cable, PC
Application Software on CD-ROM and operating instructions, for use on
110V/60Hz. |
|